Photometer pH, Free Chlorine and Total Chlorine, Alkalinity, Cyanuric Acid Hanna
HI-97104 is an advanced portable photometer for the measurement of pH, Alkalinity, free chlorine & total chlorine, and Cyanuric Acid in water. This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.
(επεξεργασία με το Πρόσθετο Διαβεβαίωση Πελατών)
(επεξεργασία με το Πρόσθετο Διαβεβαίωση Πελατών)
(επεξεργασία με το Πρόσθετο Διαβεβαίωση Πελατών)
The internal reference system of the HI-97104 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.
High Efficiency Light Source:
LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
High Quality Filters:
Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.
Greater Light Yield:
A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.
CAL Check Functionality:
Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.
Alkalinity Range 0 to 500 mg/L (as CaCO3)
Environment 0 to 50°C (32 to 122°F); relative humidity: 100% (IP67, floating case)
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Chlorine Range (all ranges) 0.00 to 5.00 mg/L (as Cl2)
Chlorine Resolution 0.01 mg/L
pH Resolution 0.1 pH
Alkalinity Resolution 1 mg/L
Cyanuric Acid Resolution 1 mg/L
Battery Type/Life 1.5V AA battery (x3) / > 800 measurements (without backlight)
Display 128 x 64 pixel B/W LCD with backlight
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0")
Weight 380 g (13.4 oz.) with batteries
Logging Memory 50 measurement
Bandpass Filter Bandwidth 8 nm
pH Method adaptation of Phenol Red method
Chlorine Method adaptation of the EPA DPD 330.5 method
Cyanuric Acid Method adaptation of the turbidimetric method
Automatic Shut-Off After 15 minutes of inactivity (30 minutes before a READ measurement)
Logging Type automatic logging
Alkalinity Method Colorimetric method
GLP date, time of last calibration
Ordering Information HI-97104 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate. Kit: HI-97104C is supplied with CAL-Check standards, cuvettes (2), caps, (2), plastic inserts for cuvettes (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.
Measurement system Light Source Light emitting diode
Cuvette Type round, 24.6 mm diameter (22 mm inside)
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 525 nm
Chlorine Accuracy ±0.03 mg/L ±3% of reading
pH Accuracy ±0.1 pH @ 25°C
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading @ 25°C
Bandpass Filter Wavelength Accuracy ±1.0 nm
Alkalinity Accuracy ±5 mg/L @ 25°C
No customer reviews for the moment.
